Surgical Drain Securement for Postoperative Complications
What You Need to Know Before You Apply
What is the purpose of this trial?
This trial tests a new device called the K-LOCK™ to determine if it secures surgical drains more effectively than traditional stitches. The goal is to enhance patient comfort after surgery and reduce complications related to surgical drains. Participants will be assigned to one of two groups: one using the K-LOCK™ and the other using traditional stitches. Ideal candidates are those undergoing plastic or reconstructive surgery with expected surgical drains. As an unphased trial, this study allows participants to contribute to innovative surgical advancements.
Do I need to stop my current medications for the trial?
The trial information does not specify whether you need to stop taking your current medications.
What prior data suggests that the K-LOCK device is safe for surgical drain securement?
Why are researchers excited about this trial?
Researchers are excited about the K-Lock device because it offers a new way to secure surgical drains post-operation. Unlike traditional sutures, which require stitches to hold drains in place, the K-Lock device is designed to be easier to apply and remove, potentially reducing patient discomfort. Additionally, the K-Lock device may lower the risk of complications like infections or leaks, which are common concerns with traditional methods. This innovation could lead to quicker recovery times and improved outcomes for patients undergoing surgery.
What evidence suggests that the K-Lock device is effective for reducing postoperative complications?
Who Is on the Research Team?
Bennett W Calder, MD
Principal Investigator
Wake Forest University Health Sciences
Are You a Good Fit for This Trial?
This trial is for adults over 18 who are undergoing surgery that requires drains and can sign an English consent form. It's specifically for patients of the Department of Plastic and Reconstructive Surgery. People with allergies to skin adhesives or incompatible drain sizes, or those unable to sign the consent in English cannot participate.Inclusion Criteria
Exclusion Criteria
Timeline for a Trial Participant
Screening
Participants are screened for eligibility to participate in the trial
Treatment
Patients undergo surgery with drains secured using either the K-Lock device or traditional suture-based methods
Postoperative Monitoring
Subjects are followed weekly via electronic medical record for complications and return to clinic for regular follow-up appointments
Follow-up
Participants are monitored for safety and effectiveness after treatment, including a final survey and evaluation of the drain site
What Are the Treatments Tested in This Trial?
Interventions
- K-Lock
Trial Overview
The study is testing a new sutureless device called K-LOCK™ against traditional sutures for securing surgical drains. The goal is to see if K-LOCK™ improves patient quality of life and reduces complications after surgery.
How Is the Trial Designed?
2
Treatment groups
Experimental Treatment
Active Control
K-Lock securement device
Traditional suture securement
Find a Clinic Near You
Who Is Running the Clinical Trial?
Wake Forest University Health Sciences
Lead Sponsor
University of Mississippi Medical Center
Collaborator
Published Research Related to This Trial
Citations
First-in-human Testing of a Novel Sutureless Drain ...
The K-LOCK enhances the patient experience with surgical drains and offers a reliable, standardized alternative to traditional drain securement.
2.
clinicaltrials.gov
clinicaltrials.gov/study/NCT05251753?locStr=Winston-Salem,%20NC&country=United%20States&state=North%20Carolina&city=Winston-Salem&distance=50&term=drain&rank=1Evaluation of a Novel Sutureless Drain Securement Device
The purpose of this study is to evaluate an investigational sutureless drain securement device (K-Lock) and compare this device to standard drain securement.
Surgical Drain Securement for Postoperative Complications
The modified surgical drain-guided percutaneous catheter drainage technique was successfully used in 24 patients with a high technical success rate of 91.7% and ...
4.
trial.medpath.com
trial.medpath.com/clinical-trial/5a46b83099b2d266/nct06916286-surgical-drain-secure-patient-quality-lifeEvaluating the Effect of Surgical Drain Securement on Patient ...
The objective of this study is to evaluate whether surgical drain securement with a novel sutureless device (K-LOCKTM) will improve patient quality of life ...
5.
ctv.veeva.com
ctv.veeva.com/study/evaluating-the-effect-of-surgical-drain-securement-on-patient-quality-of-life-and-postoperative-draiEvaluating the Effect of Surgical Drain Securement on Patient ...
The K-LOCK™ Device is a novel sutureless drain securement device that may improve patient experiences with surgical drains. Full description.
Information for Hospitals
The K-LOCK™ device offers superior stability for surgical drains, leading to fewer risks of complications, adverse events, and a smoother post-operative ...
Complications Related to the Securement Device in ...
Patients were followed throughout their entire catheter course, and complications included infection, occlusion, phlebitis, accidental dislodgement, ...
Unbiased Results
We believe in providing patients with all the options.
Your Data Stays Your Data
We only share your information with the clinical trials you're trying to access.
Verified Trials Only
All of our trials are run by licensed doctors, researchers, and healthcare companies.